1. Regular inspection
Check the end voltage and internal resistance of each unit battery. For the 12V unit battery, if the end voltage difference between the battery of each unit exceeds 0.4V or the internal resistance of the battery is more than 80mq or more, the battery should be balanced to restore the internal resistance of the battery to the battery's internal resistance. And eliminate the end voltage imbalance between the batteries. The charging voltage at a balanced charging can be taken 13.5 ~ 13.8V. Most of the batteries that are well -balanced charging can be restored to less than 30mq.
During the operation of the PS power supply, the above -mentioned unevenness generated by the battery characteristics of each unit may rely on the charging circuit inside the UPS power supply to eliminate it. For groups, if they are not taken off in time, their unevenness will become more and more serious.
2. Re -floating charging
The PS power supply is stopped for more than 10 days. Before reorganizing, the UPS power supply should be activated without loading.
The IPS power supply has been in a fluttering state for a long time without discharge, which is equivalent to being in the state of "storage and standing". If this state lasted too long, causing the battery to be scrapped due to "storage for too long". It mainly manifested that the internal resistance of the battery increased, and the internal resistance could reach a few Q.
We found that at room temperature at 20 ° C, after 1 month of storage, the capacity of the battery available was about 97%of its rated value. If it was stored for 6 months, its available capacity became 80%of the rated capacity. If the storage temperature rises, its use capacity will be reduced.
Therefore, it is recommended that users should deliberately unplug the electricity input every 20 ° C to allow the UPS power supply to work in the state of energy from the battery to the inverter. However, this operation should not be too long. When the load is about 30%of the rated output, it can be discharged for about 10min.
3. Reduce depth discharge
The service life of electricity is closely related to the depth of its discharge. The lighter the load of the UPS power supply, the larger the capacity of the power -to -use capacity to the rated capacity when the municipal power supply is interrupted. In this case, when the UPS power supply is automatically shut down when the battery voltage is too low, the battery is being automatically shut down. The depth of discharge is deeper.
Read recommendations:
solar energy storage Processor
Hysincere 500W Portable Power Station Solar Powered
Lithium battery non graphite negative electrode.solar battery storage system
Lithium battery characteristics
Last article:How to extend the battery life of electric vehicles.lithium golf cart batteries Production
Next article:Why do you need a high -pressure battery?lithium batteries for boats maker
related suggestion
solar power storage sales
2023-03-20lithium trolling motor battery sales
2023-03-22lithium batteries for boats Factory
2023-04-07lithium ion golf cart batteries Vendor
2023-03-22solar battery storage system price
2023-03-20solar energy storage wholesale
2023-03-2048v lithium golf cart battery
2023-05-08lithium trolling motor battery
2023-05-08best solar generator for home
2023-05-08solar power storage
2023-05-08solar generator kits
2023-05-08solar powered generator for camping
2023-05-08Lithium Replacing Lead-Acid LiFePo4 Battery Pack 12V 200Ah
2022-09-1912 volt Lithium LiFePo4 Battery Pack 12V 50Ah Cell 4000+ Cycles Group 24 Compact for RV Trolling Motor Solar Power
2025-02-27+85 Operating Lithium Battery Li Ion 18650 26650 Cell
2023-02-1412V 400Ah LiFePo4 Lithium Replacing Lead-acid Battery Pack
2023-06-21Lithium Ion Battery 18650 Pack 11.1V 12V 2000mAh 3000mAh
2023-02-0918650 vs 26650 Lithium-Ion Batteries: A Comparative Analysis for Optimal Performance
2025-03-19Explanation of the Development Trends of the Global Lithium Battery Industry.portable power station solar
2023-10-08What is hjt battery?
2022-11-04Introduction to Lithium Battery Electrolyte.solar backup generator
2023-07-21Design specification for lithium batteries.golf cart batteries for sale
2023-06-28Lithium battery capacity Electrolyte decomposition.solar battery for house Manufacturing
2023-04-18What is the reason for the discharge and heating of 18650 lithium batteries.solar battery storage system
2023-06-25What is the difference between polymer lithium battery and liquid battery
2022-12-30What is the HIT battery?
2023-02-22The correct way to use electric vehicle lithium batteries.deep cell marine battery price
2023-03-11